rtc: m41t80: avoid out of range year values

Avoid saving an out of range year value to the RTC. Reading that value
from the RTC again returns a totally wrong time value. For Example

    $ timedatectl set-ntp no
    $ timedatectl set-time "1990-01-01 12:12:00"
    # Reboot
    rtc-m41t80 0-0068: setting system clock to 2090-01-01 12:12:35 UTC (3786955955)

Signed-off-by: Stefan Christ <s.christ@phytec.de>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
diff --git a/drivers/rtc/rtc-m41t80.c b/drivers/rtc/rtc-m41t80.c
index a82937e..d107a8e 100644
--- a/drivers/rtc/rtc-m41t80.c
+++ b/drivers/rtc/rtc-m41t80.c
@@ -176,7 +176,13 @@
 		bin2bcd(tm->tm_mday) | (buf[M41T80_REG_DAY] & ~0x3f);
 	buf[M41T80_REG_MON] =
 		bin2bcd(tm->tm_mon + 1) | (buf[M41T80_REG_MON] & ~0x1f);
+
 	/* assume 20YY not 19YY */
+	if (tm->tm_year < 100 || tm->tm_year > 199) {
+		dev_err(&client->dev, "Year must be between 2000 and 2099. It's %d.\n",
+			tm->tm_year + 1900);
+		return -EINVAL;
+	}
 	buf[M41T80_REG_YEAR] = bin2bcd(tm->tm_year % 100);
 
 	if (i2c_transfer(client->adapter, msgs, 1) != 1) {